Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.352
Filtrar
1.
J Am Coll Cardiol ; 83(15): 1418-1430, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38599718

RESUMO

During the past 6 decades, there have been numerous changes in prosthetic valve endocarditis (PVE), currently affecting an older population and increasing in incidence in patients with transcatheter-implanted valves. Significant microbiologic (molecular biology) and imaging diagnostic (fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography) advances have been incorporated into the 2023 Duke-International Society for Cardiovascular Infectious Diseases infective endocarditis diagnostic criteria, thus increasing the diagnostic sensitivity for PVE without sacrificing specificity in validation studies. PVE is a life-threatening disease requiring management by multidisciplinary endocarditis teams in cardiac centers to improve outcomes. Novel surgical options are now available, and an increasing set of patients may avoid surgical intervention despite indication. Selected patients may complete parenteral or oral antimicrobial treatment at home. Finally, patients with prosthetic valves implanted surgically or by the transcatheter approach are candidates for antibiotic prophylaxis before invasive dental procedures.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/terapia , Endocardite Bacteriana/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Infecções Relacionadas à Prótese/microbiologia , Endocardite/diagnóstico , Endocardite/etiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
2.
J Am Coll Cardiol ; 83(15): 1431-1443, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38599719

RESUMO

This focused review highlights the latest issues in native valve infective endocarditis. Native valve disease moderately increases the risk of developing infective endocarditis. In 2023, new diagnostic criteria were published by the Duke-International Society of Cardiovascular Infectious Diseases group. New pathogens were designated as typical, and findings on computed tomography imaging were included as diagnostic criteria. It is now recognized that a multidisciplinary approach to care is vital, and the role of an "endocarditis team" is highlighted. Recent studies have suggested that a transition from intravenous to oral antibiotics in selected patients may be reasonable, and the role of long-acting antibiotics is discussed. It is also now clear that an aggressive surgical approach can be life-saving in some patients. Finally, results of several recent studies have suggested there is an association between dental and other invasive procedures and an increased risk of developing infective endocarditis. Moreover, data indicate that antibiotic prophylaxis may be effective in some scenarios.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Endocardite/diagnóstico , Endocardite/etiologia , Endocardite Bacteriana/diagnóstico , Tomografia Computadorizada por Raios X , Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Próteses Valvulares Cardíacas/efeitos adversos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
3.
J Cardiothorac Surg ; 19(1): 164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561823

RESUMO

BACKGROUND: Mitral regurgitation is a frequent valvular disease, with an increasing prevalence. We analyzed the short-term outcomes of mitral valve repair procedures conducted in our clinic using a new semirigid annuloplasty ring featuring a gradual saddle shape design. METHODS: We retrospectively analyzed mitral valve repair surgeries performed at our Institution between December 2019 and November 2021 with the MEMO 4D semirigid annuloplasty ring. RESULTS: In total, 53 patients were included in the study. Mean patient age was 63.6 ± 11.7 years. Most patients presented with degenerative mitral valve regurgitation (N = 44; 83%). The grade of mitral regurgitation was equal or more than 3 + in 98.1% of the patients (N = 52). The most used ring size was size 34 mm (N = 30, 56.6%). There was no intraoperative or hospital mortality. No cases of stroke, bleeding, endocarditis or other major complications occurred. At discharge, most patients were in NYHA class I. Postoperative echocardiographic results showed no (90.6%) or 1+ (5.7%) mitral valve regurgitation. Only 1 patient (1.9%) presented with mitral valve regurgitation grade 2+. Mean postoperative transvalvular gradient was low (mean = 3.3 ± 1.2 mmHg). No cases of LVOT obstruction or systolic anterior motion occurred. CONCLUSIONS: Our series showed excellent mitral valve competency and very satisfactory early clinical outcomes. The transesophageal echocardiographic follow-up, despite obtained in a limited number of patients, further confirmed the effectiveness of findings of this preliminary experience.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Anuloplastia da Valva Mitral/efeitos adversos , Ecocardiografia , Resultado do Tratamento
4.
J Cardiothorac Surg ; 19(1): 176, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576022

RESUMO

BACKGROUND: Mechanical heart valve replacement is a standard treatment for severe valvular disorders. The use of mono-leaflet valves has decreased recently. Recognizing the echocardiographic features of mono-leaflet and bileaflet valves is crucial for accurate complication diagnosis and proper management. CASE PRESENTATION: A 65-year-old female with mono-leaflet mitral and bileaflet tricuspid valves underwent an echocardiographic assessment. This simple educational case provides a unique opportunity to compare the echocardiographic features of these valves within a single patient. CONCLUSION: There is a crucial need for clinicians, particularly those in training, to differentiate between mono-leaflet and bileaflet mechanical heart valves adeptly. With mono-leaflet valves decreasing in prevalence, proficiency in recognizing the echocardiographic nuances of each type is imperative. Failure to do so may result in misdiagnoses and inappropriate management. This underscores the significance of continuous education and vigilance in echocardiographic assessments to ensure optimal patient care.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral , Feminino , Humanos , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Ecocardiografia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Desenho de Prótese
5.
Echocardiography ; 41(4): e15804, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38578295

RESUMO

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Assuntos
Bioprótese , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Estenose da Valva Tricúspide , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Bioprótese/efeitos adversos , Constrição Patológica , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Resultado do Tratamento , Desenho de Prótese , Falha de Prótese
6.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627820

RESUMO

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombocitopenia , Humanos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Bioprótese/efeitos adversos , Desenho de Prótese , Próteses Valvulares Cardíacas/efeitos adversos , Trombocitopenia/etiologia , Fatores de Risco , Progressão da Doença
7.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589959

RESUMO

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Assuntos
Bioprótese , Endocardite , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Micoses , Humanos , Masculino , Adulto Jovem , Aorta/cirurgia , Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Endocardite/diagnóstico , Endocardite/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
8.
Circ Cardiovasc Imaging ; 17(4): e016435, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38626096

RESUMO

Heart valve replacement has steadily increased over the past decades due to improved surgical mortality, an aging population, and the increasing use of transcatheter valve technology. With these developments, prosthetic valve complications, including prosthetic valve endocarditis, are increasingly encountered. In this review, we aim to characterize the manifestations of prosthetic valve endocarditis using representative case studies from our institution to highlight the advances and contributions of modern multimodality imaging techniques.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Idoso , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Imagem Multimodal , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/terapia
9.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
10.
Curr Probl Cardiol ; 49(5): 102478, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38437930

RESUMO

Transcatheter Aortic Valve Replacement (TAVR) marks a significant advancement in treating aortic stenosis (AS), especially for patients with high surgical risks. This concise review outlines TAVR's development, its broader application to include lower-risk patients, and innovations in the device and procedural technology. Clinical trials, notably the PARTNER series, affirm TAVR's efficacy, showing it matches or surpasses surgical aortic valve replacement (SAVR) in mortality reduction, hemodynamic benefits, and symptom alleviation, including heart failure. However, TAVR entails complications such as paravalvular leakage (PVL), conduction disorders, and increased cerebrovascular event risks. We evaluate these issues, their prevalence, causative factors, and clinical consequences, emphasizing improvements in valve design and technique that have significantly lowered PVL rates. The role of aortic valve anatomy and calcification in PVL and conduction issues is analyzed, underlining the necessity for meticulous patient selection and procedural planning. Further, the review delves into cerebrovascular event risks, their origins, and preventative strategies, including cerebral protection devices and the judicious use of anticoagulant and antiplatelet therapies. TAVR presents a less invasive, promising alternative to SAVR, but requires careful complication management to optimize patient results. Ongoing innovation and research are vital for advancing TAVR's techniques, improving valve designs, and extending its reach, thereby enhancing AS patients' quality of life.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Fatores de Risco
11.
J Am Heart Assoc ; 13(7): e033176, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533939

RESUMO

BACKGROUND: It remains controversial whether prosthesis-patient mismatch (PPM) impacts long-term outcomes after surgical aortic valve replacement. We aimed to evaluate the association of PPM with mortality, rehospitalizations, and aortic valve reinterventions. METHODS AND RESULTS: We performed a systematic review with meta-analysis of reconstructed time-to-event data of studies published by March 2023 (according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses). Sixty-five studies met our eligibility criteria and included 122 989 patients (any PPM: 68 332 patients, 55.6%). At 25 years of follow-up, the survival rates were 11.8% and 20.6% in patients with and without any PPM, respectively (hazard ratio [HR], 1.16 [95% CI, 1.13-1.18], P<0.001). At 20 years of follow-up, the survival rates were 19.5%, 12.1%, and 8.8% in patients with no, moderate, and severe PPM, respectively (moderate versus no PPM: HR, 1.09 [95% CI, 1.06-1.11], P<0.001; severe versus no PPM: HR, 1.29 [95% CI, 1.24-1.35], P<0.001). PPM was associated with higher risk of cardiac death, heart failure-related hospitalizations, and aortic valve reinterventions over time (P<0.001). Statistically significant associations between PPM and worse survival were observed regardless of valve type (bioprosthetic versus mechanical valves), contemporary PPM definitions unadjusted and adjusted for body mass index, and PPM quantification method (in vitro, in vivo, Doppler echocardiography). Our meta-regression analysis revealed that populations with more women tend to have higher HRs for all-cause death associated with PPM. CONCLUSIONS: The results of the present study suggest that any degree of PPM is associated with poorer long-term outcomes following surgical aortic valve replacement and provide support for implementation of preventive strategies to avoid PPM after surgical aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Falha de Prótese , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Fatores de Risco , Desenho de Prótese
12.
Int J Cardiol ; 404: 131968, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38503347

RESUMO

BACKGROUND: Prosthetic valve thrombosis (PVT) is a severe and life-threatening complication. Surgery and thrombolytic therapy (TT) carry a high risk, and in several circumstances, optimal anticoagulation with unfractionated heparin (UFH) infusion may be an alternative treatment. This study aimed to assess the results of UFH in patients diagnosed with both obstructive and non-obstructive PVT. METHODS: This observational retrospective study enrolled patients who had contraindications for TT and surgery underwent UFH therapy. RESULTS: A total of 136 patients were enrolled [male: 55 (40.4%), mean age: 50.3 ± 14.6 years] in the study. In the successful group, 66 patients (48,5%) showed >75% regression in the thrombus burden without facing death or major non-fatal complications.In the unsuccessful group, 56 had less than a 50% reduction in thrombus load and 14 (10.3%) suffered major complications. The presence of obstruction (27.1% vs. 12.1%; p = 0.028), thrombus area 1.1 cm2 vs. 0.8 cm2; p = 0.005] and the duration of UFH treatment (15.1 vs. 11.8 (days); p = 0.005) were significantly higher in the unsuccessful UFH group.In multivariate regression analyses the presence of obstruction (RR: 3.088, p = 0.020), increased thrombus area (RR: 2.400; p = 0.015), and increased duration of UFH therapy (RR: 1.073 95%, p = 0.012) were identified as independent predictive parameters for a failed UFH therapy. CONCLUSIONS: This study suggests that UFH therapy may be considered a relatively beneficial treatment strategy for some patients with PVT. The most significant factors affecting success are the obstructive nature and area of the thrombus.


Assuntos
Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Trombose , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Heparina , Estudos Retrospectivos , Próteses Valvulares Cardíacas/efeitos adversos , Doenças das Valvas Cardíacas/diagnóstico , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologia , Anticoagulantes , Heparina de Baixo Peso Molecular
13.
J Infect Public Health ; 17(4): 712-718, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484416

RESUMO

BACKGROUND: Infective endocarditis continues to be a significant concern and may be undergoing an epidemiological transition. METHODS: Were studied 1804 consecutive episodes of infective endocarditis between 1978 and 2022. The mean age was 48 ( ± 19), and 1162 (64%) patients were male. Temporal trends in demographic data, comorbidities, predisposing conditions, microorganisms, complications and in-hospital death have been studied over the decades (1978-1988, 1989-1999, 2000-2010 and 2011-2022). The outcomes and clinical characteristics were modeled using nonlinear cubic spline functions. FINDINGS: Valve surgery was performed in 50% of the patients and overall in-hospital mortality was 30%. From the first to the fourth decade studied, the average age of patients increased from 29 to 57 years (p < 0.001), with significant declines in the occurrence of rheumatic valvular heart disease (15% to 6%; p < 0.001) and streptococcal infections (46% to 33%; p < 0.001). Healthcare-associated infections have increased (9% to 21%; p < 0.001), as have prosthetic valve endocarditis (26% to 53%; p < 0.001), coagulase-negative staphylococcal infections (4% to 11%; p < 0.001), and related-complications (heart failure, embolic events, and perivalvular abscess; p < 0.001). These changes were associated with a decline in adjusted in-hospital mortality from 34% to 25% (p = 0.019). INTERPRETATION: In the 44 years studied, there was an increase in the mean age of patients, healthcare-related, prosthetic valve, coagulase-negative staphylococci/MRSA infections, and related complications. Notably, these epidemiological changes were associated with a decline in the adjusted in-hospital mortality.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Endocardite Bacteriana/cirurgia , Mortalidade Hospitalar , Coagulase , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Endocardite/epidemiologia , Staphylococcus , Infecções Estafilocócicas/complicações
14.
J Cardiothorac Surg ; 19(1): 143, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504317

RESUMO

BACKGROUND: Coronary artery obstruction after percutaneous aortic replacement is a complication with high short-term mortality secondary to the lack of timely treatment. There are various predictors of coronary obstruction prior to valve placement such as the distance from the ostia, the degree of calcification, the distance from the sinuses; In such a situation some measures must be taken to prevent and treat coronary obstruction. CASE PRESENTATION: An 84-year-old male, with severe aortic stenosis and high surgical risk, who was treated with TAVR. However, during the deployment of the valve he presented hemodynamic instability secondary to LMCA obstruction. The intravascular image showed obstruction of the ostium secondary to the displacement of calcium that he was successfully treated with a chimney stent technique. CONCLUSIONS: The high degree of calcification and the left ostium near the annulus are conditions for obstruction of the ostium at the time of valve release; In this context, provisional stenting prior to TAVR in patients at high risk of obstruction should be considered as a safe prevention strategy to achieve the success of the procedure.


Assuntos
Estenose da Valva Aórtica , Calcinose , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Oclusão Coronária/etiologia , Calcinose/complicações , Calcinose/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
15.
J Cardiothorac Surg ; 19(1): 114, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468271

RESUMO

Prosthetic valve thrombosis (PVT) in aortic valve and its complication coronary embolism is a very rare condition. Diagnosis and treatment process is challenging. We present a young patient with acute myocardial infarction who underwent mechanical aortic valve replacement (AVR) operation one month earlier. Percutaneous coronary intervention was performed and it was succesful. Transeasophageal ecocardiography (TEE) was performed. Thrombus was seen on the mechanical aortic valve and thrombolytic therapy was initiated. Control TEE was performed and there was no signs of thrombi. The patient was discharged healthfully with anticoagulant and antiaggregan.


Assuntos
Doença da Artéria Coronariana , Embolia , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Humanos , Valva Aórtica/cirurgia , Infarto do Miocárdio/cirurgia , Infarto do Miocárdio/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Embolia/cirurgia , Embolia/complicações , Doenças das Valvas Cardíacas/cirurgia , Doença da Artéria Coronariana/complicações
16.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465492

RESUMO

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Feminino , Humanos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tórax , Próteses Valvulares Cardíacas/efeitos adversos , Dor no Peito/etiologia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
17.
Kyobu Geka ; 77(3): 191-195, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465491

RESUMO

We experienced a case of surgical aortic valve re-replacement due to structural valve deterioration caused by pannus formation 4 years after transcatheter aortic valve replacement( TAVR). The patient underwent surgery because the mean transvalvular pressure gradient increased to 48 mmHg on echocardiography. Contrast-enhanced computed tomography (CT) was useful for predicting the site of adhesion to surrounding tissue preoperatively and exploring the presence of the pannus. Intraoperative findings showed the TAVR valve was covered with neointima except around the origins of the left and right coronary arteries and was firmly adhered to the surrounding tissues. As residual pannus was present in the subvalvular tissues, it was carefully removed. The explanted TAVR valve functioned well with good opening and closure. The postoperative course was uneventful. Pannus formation can result from mechanical stress. TAVR valves put significantly greater stress on the left ventricular outflow tract than surgical valves and may be more likely to cause pannus formation.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Pannus , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
18.
Echocardiography ; 41(3): e15783, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38456307

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is gradually becoming an alternative therapy for patients who cannot adapt to surgical treatment or have contraindications. OBJECTIVES: The purpose of this study was to investigate the value of echocardiography in the evaluation of severe AR patients treated with TAVR and to analyze the correlations with postprocedural complications to improve the evaluation and screening of patients. METHODS: We retrospectively analyzed clinical and echocardiographic data of 70 patients with severe AR. Periaortic valve structures were carefully measured by esophageal echocardiography (TEE) and compared with the multilayer slice computed tomography (MSCT) findings. Real-time three-dimensional esophageal echocardiography (RT-3D TEE) was monitored during the operation, and a 30-day postprocedural follow-up was performed. The relationship between postprocedural complications and patients' clinical data or periaortic valve structures was analyzed by multifactorial analysis to identify relevant predictors of complications. RESULTS: The TEE measurements of periaortic valve structures were in good agreement with the MSCT measurements. Among the patients who underwent successful operations, both left atrial (LA) and left ventricular (LV) diameters were reduced, and the left ventricular ejection fraction (LVEF) was improved 30 days after TAVR compared with the preprocedural period (P < .05). Permanent pacemakers were implanted in 15 patients. The presence of preprocedural right bundle branch block (RBBB) (OR: 2.93; 95% CI: 1.18-12.70; P = .01) was an independent factor for permanent pacemaker implantation after TAVR. CONCLUSIONS: Echocardiography plays an extremely important role in TAVR procedures. The presence of preprocedural RBBB can be an independent predictor of postprocedural pacemaker implantation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/cirurgia , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Função Ventricular Esquerda , Ecocardiografia/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
19.
Kyobu Geka ; 77(2): 106-109, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459859

RESUMO

INTRODUCTION: Pulsed lavage irrigation (PLI) is a procedure used to wash contaminated soft tissues and prevent infection in orthopedic surgery. We applicated PLI for surgical treatment of infective endocarditis( IE). SUBJECTS AND METHODS: From January 2017 to June 2021, 6 cases underwent surgical treatment IE using PLI. We investigated an efficacy of PLI. RESULTS: Infected valves were mitral valve in 4 cases, aortic valve in 1 case, and aortic prosthetic valve in 1 case. The performed procedures were mitral valve plasty in 4 cases, aortic valve replacement in 1 case, and 1 removal of vegetation on the aortic prosthetic valve. No recurrence of IE or no deterioration of the native valve or the prosthetic valve was observed in follow-up periods. CONCLUSION: PLI was useful for surgical treatment of IE because of no recurrence of IE or no deterioration of native mitral valves or the aortic prosthetic valve.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Irrigação Terapêutica/efeitos adversos , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/complicações , Endocardite/cirurgia , Valva Mitral/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...